What Is Unbonded PC Strand? Uses, Structure, and Key Specifications

24, Nov. 2026

 

What Is Unbonded PC Strand? Uses, Structure, and Key Specifications

Unbonded PC strand is a high-strength steel tendon used to prestress concrete, most often in post-tensioned construction. It is typically made from seven-wire prestressing strand, coated with corrosion-inhibiting grease and enclosed in a plastic sheath so the steel can move relative to the surrounding concrete during stressing. Buyers should assess its strand diameter, strength grade, coating and sheath requirements, applicable standard, and compatibility with the project’s anchorage and installation system.

Check now

Unlike bonded post-tensioning systems, an unbonded tendon is not grouted into a duct along its length after stressing. This construction affects how the tendon transfers force and how it must be detailed, installed, inspected, and protected. Below, we explain the structure, common uses, specification choices, and the information to prepare when sourcing unbonded PC strand.

Key Takeaways

  • Unbonded PC strand is generally a seven-wire steel strand protected by grease and a continuous plastic sheath.
  • It is commonly used in post-tensioned concrete slabs and other systems designed for unbonded tendons.
  • Common nominal strand diameters include 12.7 mm and 15.2 mm; confirm the required size and tolerances against the project specification.
  • Selection should follow the structural design, applicable standards, anchorage requirements, and site installation conditions—not diameter alone.

What Is Unbonded PC Strand?

“PC” means prestressed concrete, and “strand” refers to a group of steel wires twisted together to form a tensile element. In an unbonded post-tensioning system, the strand is protected along its length by a corrosion-inhibiting coating and an impermeable plastic sheath. The tendon is placed in the concrete before casting, then tensioned after the concrete reaches the strength required by the design.

During stressing, the strand elongates and applies a compressive force to the concrete through its anchorages. The sheath prevents direct bonding between the strand and the surrounding concrete along the tendon length, allowing relative movement as the tendon is stressed. The system’s performance depends on the complete tendon assembly and design, including strand, protection, anchorages, and installation—not just the steel strand in isolation.

Structure and Core Functions

Seven-wire steel strand

A common construction is one central wire surrounded by six outer wires. The twisted arrangement provides a compact, high-strength tensile element for prestressing applications. A frequently specified strength class is 1860 MPa, but this is an example rather than a universal requirement; buyers should verify the required tensile properties and test criteria in the governing project specification.

Grease coating and plastic sheath

The grease coating and plastic sheath provide corrosion protection and help maintain the tendon’s unbonded condition. Their material, coverage, continuity, and compatibility with the project environment should be specified and checked in accordance with the applicable requirements. Damage, cuts, or poorly protected end regions can compromise the protection system, so handling and installation controls matter.

Anchorage and stressing system

Anchorage hardware transfers the tendon force to the concrete at the ends, while stressing equipment applies the specified force during construction. The strand must be compatible with the selected anchorage system and installation procedure. Engineers and contractors should coordinate tendon layout, stressing sequence, concrete strength requirements, and inspection before work begins.

Uses and Application Scenarios

Unbonded PC strand is commonly associated with post-tensioned floor and roof slabs in buildings, including applications where the structural design calls for tendons that can move within their sheaths. It may also be used in other concrete elements designed for unbonded post-tensioning. Its suitability depends on the project’s structural calculations, exposure conditions, detailing, and local codes.

For more information, please visit DALU.

For a buyer, the important distinction is not simply whether a project uses prestressing, but which prestressing system the engineer has designed. Unbonded and bonded tendons differ in their protection, force-transfer behavior, and detailing requirements. Do not substitute one system for another without formal engineering approval.

Types and Material Options

When comparing unbonded PC strand products, clarify whether the supplier is quoting bare strand or a complete coated and sheathed tendon. Buyers may need to specify strand diameter, steel strength and mechanical properties, grease type or requirements, sheath material and dimensions, coil or package format, and end protection. Available options and terminology can vary by market and governing standard.

Common nominal strand diameters include 12.7 mm and 15.2 mm. These are widely encountered size options, not a recommendation for a particular structure; the design documents determine the required size and system configuration. Confirm whether the stated diameter refers to the steel strand and how the supplier identifies the coated product in its quotation and inspection documents.

Key Specifications Buyers Should Evaluate

  • Applicable standard: Identify the project’s required national, regional, or contractual standard and edition. Request documentation that corresponds to the specified product and production lot.
  • Nominal diameter and tolerances: Confirm the specified strand size, measurement basis, and permitted tolerances. Do not compare offers using nominal diameter alone if the quoted products are defined differently.
  • Mechanical properties: Check tensile strength, elongation, relaxation or other required characteristics, and the relevant test methods. For example, 1860 MPa is a commonly encountered strength class, but the project documents must establish the actual requirement.
  • Protection system: Specify coating and sheath requirements, including material, coverage, dimensions, and protection at ends or connections where applicable.
  • System compatibility: Confirm that the tendon suits the selected anchors, wedges, stressing equipment, detailing, and installation method.
  • Documentation and traceability: Agree on certificates, inspection records, marking, packaging information, and lot identification required for receiving and project quality control.

How to Select a Supplier

Start with the approved design documents and procurement specification, then send suppliers the required strand size, strength class, applicable standard, protection details, quantity, delivery location, and requested documentation. Ask each supplier to identify clearly whether its offer covers bare strand or a complete unbonded tendon product. This makes quotations easier to compare and reduces the chance of overlooking sheath, coating, packaging, or inspection requirements.

Before placing an order, review product documentation and clarify inspection responsibilities, production and delivery schedules, packaging, and how nonconforming or damaged material will be handled. Ask how the supplier identifies batches and keeps supplied documentation linked to the delivered goods. If a requirement is unclear, resolve it with the project engineer and supplier before manufacture or shipment.

Supplier Support from DALU

As a manufacturer, supplier, and exporter of unbonded PC strand, DALU can discuss product requirements with construction buyers, contractors, and distributors. To support an accurate quotation, provide your drawings or specification, target quantity, delivery destination, applicable standard, and required strand and protection details. Our team can review the requested configuration and clarify which product information and documents are available for the order.

Conclusion: What Should You Specify?

Unbonded PC strand is a steel prestressing tendon protected by grease and a plastic sheath, used in concrete systems designed for unbonded post-tensioning. Its structure allows the strand to move relative to the surrounding concrete along its length, while anchors transfer the stressing force at the ends. Common diameters such as 12.7 mm and 15.2 mm, and strength classes such as 1860 MPa, are reference points—not substitutes for project requirements.

For your next step, confirm the tendon system with the engineer of record and prepare a complete procurement specification covering size, mechanical properties, protection, standard, anchorage compatibility, quantity, and documentation. Send those requirements to DALU for a product and quotation discussion. A clearly defined specification is the most practical way to compare suppliers and source unbonded PC strand that fits the project.

If you want to learn more, please visit our website Unbonded PC Strand.